CB-24HVLS Fan
$6,220.00
CB-24HVLS Fan. Experience the ultimate airflow with the CB-24HVLS by Cool Boss! Featuring an intuitive design, this HVLS fan offers unmatched cooling potential to large spaces, providing superior performance and comfort. Keep your environment cool and comfortable with Cool Boss and its cutting-edge
The CB-24HVLS is a 24-foot high-volume, low-speed (HVLS) ceiling fan built to move huge amounts of air across large shops, warehouses, and work areas. With five blades turning at up to 55 RPM, the CB-24HVLS moves up to 524,422 CFM of air while running quietly on a long-life magnet motor. It runs on 208-230 VAC single phase power, draws just 5 amps, and is UL certified and Intertek ETL listed.
This guide covers the CB-24HVLS specifications, how HVLS fans work, where this fan fits best, installation planning, maintenance, and answers to common questions. If you are outfitting a facility with shop equipment and want a cooler, more comfortable workspace, the CB-24HVLS is worth a close look.
Features
Energy-efficient
Enhance productivity
Improves air ventilation
User-friendly operation
Magnet motor extends life
Low noise levels
Durable construction
Fan diameter: 24 ft. / 7.3 m
Motor and Mount: 11.75 in. / 320 mm
Motor Diameter: 17.25 in. / 440 mm
Blade to Motor: 8.75 in. / 220 mm
RPM: 55 RPM Max.
Number of Blades: 5
Air Volume: 524,422 cfm / 14,850 cmm
Fan Hanging Weight: 295.5 lbs. / 134 kg
Voltage/Current: 208-230 VAC, 5 Amps
Frequency/Phase: 50/60 Hz, 1 Ph.
UL Certification: Yes
Intertek ETL Listed: Yes
Ceiling Height Min.: 11 ft. / 3.5 m
Control Cable Length: 80 ft. / 25 m
Operating Temperature : +5° to +131° F / -15° to +55° C
Operating Humidity: <95% Non-Condensing
CB-24HVLS Specifications
- Fan diameter: 24 ft. (7.3 m)
- Number of blades: 5
- Speed: 55 RPM maximum
- Air volume: 524,422 CFM (14,850 CMM)
- Motor and mount: 11.75 in. (320 mm)
- Motor diameter: 17.25 in. (440 mm)
- Blade to motor: 8.75 in. (220 mm)
- Fan hanging weight: 295.5 lbs. (134 kg)
- Voltage/current: 208-230 VAC, 5 amps
- Frequency/phase: 50/60 Hz, single phase
- Minimum ceiling height: 11 ft. (3.5 m)
- Control cable length: 80 ft. (25 m)
- Operating temperature: +5°F to +131°F (-15°C to +55°C)
- Operating humidity: below 95%, non-condensing
- UL certification: yes
- Intertek ETL listed: yes
What Is an HVLS Fan?
HVLS stands for high volume, low speed. Instead of a small fan spinning very fast, an HVLS fan uses very long blades that turn slowly. The CB-24HVLS has a 24-foot diameter and a top speed of just 55 RPM. Because the blades are so long, each turn moves a massive column of air.
That air flows down to the floor and then spreads out in all directions, creating a gentle, steady breeze across a wide area. One large HVLS fan can replace many small floor or wall fans, which cuts clutter, noise, and tripping hazards from cords.
Moving air makes people feel cooler even when the air temperature stays the same. This cooling effect comes from air moving across the skin and helping sweat evaporate. In a hot shop or warehouse, that steady breeze can make a big difference in comfort.
Key Features of the CB-24HVLS
Energy-Efficient Operation
The CB-24HVLS draws only 5 amps at 208-230 VAC. For a fan that moves over half a million cubic feet of air per minute, that is a modest power draw. Using a large fan to cool people directly is often far less expensive than lowering the air temperature of a whole building. The U.S. Department of Energy guidance on fans for cooling explains how moving air can improve comfort while using less energy than air conditioning.
Magnet Motor for Long Life
The fan uses a magnet motor, which is designed to extend service life. A durable motor matters for a fan that may run many hours a day through the hot months.
Low Noise Levels
Slow-turning blades make far less noise than high-speed fans. The CB-24HVLS runs at low noise levels, so workers can talk, hear alarms, and focus without the constant roar of floor fans.
Durable Construction
Built for commercial and industrial spaces, the CB-24HVLS uses durable construction suited to shops, warehouses, and other demanding environments.
User-Friendly Operation
An 80-foot control cable lets you place the controls at a convenient spot on a wall or column, well away from the fan itself.
Benefits of the CB-24HVLS in a Shop or Warehouse
- Better comfort. A steady breeze helps workers feel cooler on hot days.
- Improved ventilation. Moving air helps reduce stale air and spreads fresh air through the space.
- Higher productivity. Comfortable workers tend to stay focused and work more efficiently.
- Less clutter. One ceiling fan replaces many floor fans and cords.
- Quieter workspace. Low-speed blades make much less noise than high-speed fans.
- Drier floors. Moving air can help wet floors dry faster after cleaning.
- Year-round use. In many buildings, running an HVLS fan slowly in cold weather helps push warm air that collects near the ceiling back down to floor level.
Where the CB-24HVLS Works Best
A 24-foot fan is made for large, open spaces. The CB-24HVLS is a strong choice for:
- Automotive repair shops and service departments
- Collision repair and body shops
- Fleet maintenance garages
- Warehouses and distribution centers
- Manufacturing and assembly floors
- Agricultural buildings, barns, and equipment sheds
- Aircraft hangars
- Gyms, arenas, and event spaces
The fan requires a minimum ceiling height of 11 feet (3.5 m). In practice, larger buildings with higher ceilings give the fan more room to push air down and outward. Plan the location so the blades clear lights, sprinklers, cranes, racks, and lifts.

Planning Installation
Installing an HVLS fan is a job for qualified professionals. The CB-24HVLS has a hanging weight of 295.5 lbs. (134 kg), so it must be mounted to a structural beam or support that can safely carry the load. Have a structural engineer or experienced installer confirm the mounting point before installation.
Electrical work should be done by a licensed electrician. The fan runs on 208-230 VAC, 50/60 Hz, single phase power and draws 5 amps. Have the circuit installed according to local electrical codes and the manufacturer’s instructions.
Choose a spot for the controls where workers can reach them easily. The 80-foot control cable gives you flexibility to mount the controls on a nearby wall or column.
Check clearances carefully. In an auto shop, make sure the blades are well above the highest point a vehicle on a lift can reach. Review the location of overhead doors, lights, heaters, and sprinkler heads, too. Your installer can help make sure the fan meets local code requirements.
How Much Area Can the CB-24HVLS Cover?
The area a single HVLS fan can cover depends on the building layout, ceiling height, obstructions, and how much airflow you want at floor level. With a 24-foot diameter and up to 524,422 CFM of air volume, the CB-24HVLS is built for large open floors. Racks, walls, and parked vehicles can block airflow, so open spaces get the most benefit.
For very large buildings, many facilities use several HVLS fans spaced across the floor. An experienced installer can look at your floor plan and recommend how many fans you need and where to place them for even coverage.
Using the CB-24HVLS in an Auto Shop
Auto repair shops are often hot in the summer. Bay doors open and close all day, engines give off heat, and technicians work hard under vehicles and over fenders. Floor fans help, but they take up space, create trip hazards, and blow dust and debris around.
A ceiling-mounted CB-24HVLS keeps the floor clear and spreads a gentle breeze across many bays at once. Technicians stay cooler, and the shop stays quieter. Before installation, check the height of your car lifts with vehicles raised to full height, so the fan has plenty of clearance above the tallest vehicle you service.
Be careful about airflow in paint and prep areas. Strong air movement can carry dust onto wet paint. Many shops keep HVLS fans away from paint booths and prep stations or turn them down when that work is underway.
Operating Conditions
The CB-24HVLS is rated for operating temperatures from +5°F to +131°F (-15°C to +55°C) and humidity below 95%, non-condensing. That range covers most shops, warehouses, and agricultural buildings through hot summers and cool winters. Avoid installing the fan where it would be exposed to condensing moisture, such as directly over wash bays with heavy steam.
Safety and Certifications
The CB-24HVLS is UL certified and Intertek ETL listed. These marks show that the fan has been tested to recognized safety standards. Many building inspectors, insurers, and facility managers look for these listings when approving new equipment.
Even with certified equipment, safe installation is critical. Use qualified installers, follow the manufacturer’s instructions, and use all safety cables and hardware supplied with the fan. Workplace safety rules for overhead equipment and electrical work are covered by OSHA’s electrical safety resources.


CB-24HVLS Maintenance Tips
HVLS fans need little maintenance, but simple checks keep them running safely and smoothly:
- Inspect mounting hardware. Check bolts, brackets, and safety cables on a regular schedule.
- Clean the blades. Dust can build up on the blades over time. Clean them when the fan is off and locked out.
- Listen for changes. New noises or vibration can be a sign that something needs attention.
- Check the control cable. Make sure the 80-foot cable is secured and not damaged.
- Follow lockout procedures. Always shut off and lock out power before working on the fan.
- Keep records. A maintenance log helps you track inspections and spot issues early.
Follow the manufacturer’s maintenance schedule for specific intervals and procedures.
HVLS Fan vs. Floor Fans
Many shops start with several high-speed floor fans. Those fans are cheap to buy, but they move air in a narrow stream, make a lot of noise, take up floor space, and need cords running across walkways. Each one needs its own outlet and its own maintenance.
The CB-24HVLS replaces many of those fans with one ceiling-mounted unit. It moves air across a much wider area, runs quietly, keeps the floor clear, and uses a single 5-amp circuit. For large buildings, an HVLS fan is often the more practical and efficient long-term choice.
HVLS Fan vs. Air Conditioning
Air conditioning large, open shops and warehouses can be very expensive, especially when bay doors are open much of the day. An HVLS fan does not lower the air temperature, but it can make people feel cooler by moving air across their skin. In many facilities, the CB-24HVLS can improve comfort at a fraction of the energy cost of cooling the whole building. In buildings that do have air conditioning or heating, HVLS fans can help spread conditioned air more evenly.
Who Should Buy the CB-24HVLS?
- Shop owners who want a cooler, more comfortable workspace
- Facility managers looking to cut energy costs
- Warehouses that need better air movement over large floors
- Agricultural operations that need ventilation for people and animals
- Businesses that want to remove floor fans and cords from walkways
Getting the Most From Your CB-24HVLS
A few simple habits help you get the best results from an HVLS fan. Run the fan at higher speeds during the hottest part of the day, and slow it down when temperatures drop. Keep large obstructions away from the area directly under the fan so air can reach the floor and spread out. If you have several fans, run them together so their airflow patterns work as a system instead of fighting each other.
In cooler months, many facilities run HVLS fans at low speed to help mix warm air that rises to the ceiling back down to the work area. This can help heated buildings feel more comfortable and reduce the amount of heat that collects uselessly near the roof. Check with your installer for the best settings in your building.
Train employees on how to use the controls and who to contact if something seems wrong. A clear label on the control station showing basic settings makes the fan easy for everyone to use.

Questions to Ask Before You Buy
Before ordering the CB-24HVLS, gather a few details about your building. These answers help you and your installer confirm that a 24-foot fan is the right fit:
- What is the clear ceiling height, and where are the beams that can support a 295.5-lb. fan?
- Are there lights, sprinklers, heaters, cranes, or ducts that could interfere with the blades?
- How tall are your vehicle lifts, racks, or equipment when fully raised?
- Do you have 208-230 VAC single phase power near the planned location?
- Where should the controls be mounted so employees can reach them easily?
- Do any areas, such as paint booths, need to be kept out of the airflow?
Having these details ready makes the installation process faster and helps avoid surprises on install day.
Why Fan Size Matters
HVLS fans come in many sizes, from small units for low ceilings to very large models for warehouses. Larger diameters move more air at lower speeds and cover more floor area. A 24-foot fan like the CB-24HVLS is near the top of the size range and is designed for big, open buildings. If your space is smaller or has a low ceiling, a smaller-diameter fan may fit better. If you have a very large floor, the CB-24HVLS can move a huge volume of air from a single mounting point.
Long-Term Value of the CB-24HVLS
An HVLS fan is a long-term investment in your building. Once installed, the CB-24HVLS can run for many seasons with basic care. Its low power draw helps keep operating costs down, and its magnet motor is built for long life. Replacing a row of worn-out floor fans every few years adds up, while one well-installed ceiling fan keeps working with simple inspections. Over time, better comfort, cleaner floors, and lower energy use make the CB-24HVLS a practical upgrade for large spaces.
Frequently Asked Questions About the CB-24HVLS
How big is the CB-24HVLS?
The fan has a 24-foot (7.3 m) diameter with five blades.
How much air does it move?
The CB-24HVLS moves up to 524,422 CFM (14,850 CMM).
How fast does it spin?
The maximum speed is 55 RPM.
What power does it need?
It runs on 208-230 VAC, 50/60 Hz, single phase power and draws 5 amps.
What is the minimum ceiling height?
The minimum ceiling height is 11 feet (3.5 m).
How much does it weigh?
The fan hanging weight is 295.5 lbs. (134 kg).
Is the CB-24HVLS certified?
Yes. It is UL certified and Intertek ETL listed.
How long is the control cable?
The control cable is 80 feet (25 m) long.
What temperatures can it operate in?
It operates from +5°F to +131°F (-15°C to +55°C) at humidity below 95%, non-condensing.
What kind of motor does it use?
It uses a magnet motor designed to extend service life.
Order the CB-24HVLS Fan Today
The CB-24HVLS 24-foot HVLS fan brings powerful, quiet airflow to large shops, warehouses, and work areas. With 524,422 CFM of air volume, a long-life magnet motor, a 5-amp power draw, and UL and ETL listings, it is a practical way to make your workspace more comfortable. Contact Ironside Garage with questions about sizing, installation, or delivery, and browse our full line of shop equipment.
Related products
Atlas SBC1200 X-Large Sandblast Cabinet
Atlas SBC1200 X-Large Sandblast Cabinet with Dual Doors & Vacuum The Atlas SBC1200 sandblast cabinet takes many of the already great features of the Atlas® SBC990 blasting cabinet and doubles them. The SBC1200 sandblast cabinet has two, front and rear, extra large top open loading doors and features
Flo-Dynamics TS410 ATF Inline Exchanger
Mahle FluidPRO ATX 280 Transmission Fluid Exchange System with Adapters
Mahle FluidPRO ATX 280 Transmission Fluid Exchange System with Adapters The ATX-280 is a new design for the FluidPRO® line, featuring a large Touch display and the adoption of a new graphical interface. This upgrade is easier for the operator and automatically supports any operation of the oil flow
Ranger RS-750DS
Ranger RS-750DS The incredible RS-750DS is made out of rust-free stainless-steel and has a 1,000 lb. weight capacity that can hold some of the biggest car, truck, and SUV parts on the market. This stainless steel 53-gallon capacity spray wash cabinet can rapidly degrease dirty parts, including large

Reviews